Top Microsystems Logo Experts In Power Solutions Medical Grade Power Supply

U Channel & Enclosed - Single Output
Part Number Output Range Preset Voltage Max. Output Current Total Reg. Ripple & Noise
Type U (Convection) Type U (with forced air) & E
E1200U-M03Fw2-3.33.3V  60 +/- 1%+/-1%
E1200PQ-M33 3.3V  60200 2% Max
U1200PQ-M33 3.3V30.3W100W60200 2% Max
U1300PQ-M05  5V30W150W60300 2% Max
E1300PQ-M05  5V  60300 2% Max
E1360U-M05Fw5-65V  60 +/- 1%+/-1%
E1300PQ-M12  12V  25300 2% Max
E1400U-M12Fw12-1512V   400+/- 1%+/-1%
U1300PQ-M12  12V12.5W150W25300 2% Max
E1300PQ-M15  15V  20300 2% Max
U1300PQ-M15  15V10W150W20300 2% Max
E1400U-M18Fw16-2118V   400+/- 1%+/-1%
U1300PQ-M24  24V6.25W150W12.5300 2% Max
E1300PQ-M24  24V  12.5300 2% Max
E1400U-M24Fw22-3024V   400+/- 1%+/-1%
 
  • x1zU-MyFw. x = U (U-Chassis Type) or E (Enclosed with built-in Fan Type). or y = 03, 05, 12, 18, 24, 36 or 48. w = blank or S where S denote forced current sharing option (OR-ring diode).
  • U Series: 400W max. with 23CFM airflow or 250W max. under convection cooling; (Option: Top Cover)
  • E Series: 400W max. with built-in fan flow.
  • All output ranges are covered in agency certifications and preset output voltage for each model as above listings.
  • Providing peak power to 700W within 500uS for all models, longer duty duration need contact manufacture.
  • 1% minimum load is required to maintain the ripple and regulation.
  • Output is fully isolated.
* Dimensions: B type(5"W x 9"L x 1.6"H), U type(5"W x 8"L x 1.6"H)
 